{"product_id":"certeza-gl-110-blood-glucose-meter","title":"Certeza (Gl 110) Blood Glucose Meter","description":"\u003ch2 data-path-to-node=\"0\"\u003eDescription\u003c\/h2\u003e\n\u003cp data-path-to-node=\"1\"\u003eThe Certeza GL-110 Blood Glucose Monitor is a highly precise, user-friendly diagnostic medical instrument designed for regular monitoring of capillary blood glucose levels. Engineered with an advanced dynamic enzyme system featuring Glucose Dehydrogenase (GDH-FAD) chemistry, it offers extensive reaction stability unaffected by variations in blood oxygen levels. The system features a large, easy-to-read LCD screen, auto-coding mechanisms to eliminate manual calibration errors, and automatic strip ejection functionality, providing laboratory-grade diagnostic clarity for optimal daily diabetes care.\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"2\"\u003eIngredients\u003c\/h2\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe diagnostic device includes integrated electronic hardware. The dedicated system consumables feature:\u003c\/p\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003eGlucose Dehydrogenase enzyme matrix (GDH-FAD)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003eElectrochemical carbon-based electrodes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"5\"\u003eDrug Class\u003c\/h2\u003e\n\u003cp data-path-to-node=\"6\"\u003eIn-Vitro Diagnostic Medical Device \/ Glucose Monitoring System\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"7\"\u003eDosage Form\u003c\/h2\u003e\n\u003cp data-path-to-node=\"8\"\u003eBlood Glucose Meter (1 Kit including Glucometer, Lancing Device, Lancets, and Carrying Case)\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"9\"\u003eUses\u003c\/h2\u003e\n\u003cp data-path-to-node=\"10\"\u003eIt is used to test, screen, and log metabolic glucose indexes including:\u003c\/p\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003eDaily self-monitoring of blood glucose (SMBG) for Type 1 and Type 2 Diabetes mellitus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003eRapid quantitative measurement of extreme glycemic variances (Hyperglycemia and Hypoglycemia)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003eRoutine diagnostic tracing of capillary glucose variations in home-care and clinical health environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"12\"\u003eDosage\u003c\/h2\u003e\n\u003cp data-path-to-node=\"13\"\u003eTo be used as per doctor's prescription or tracking mandates (ranging from 1 to 4 times daily depending on individual health profiles).\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"14\"\u003eIn case of Overdose\u003c\/h2\u003e\n\u003cp data-path-to-node=\"15\"\u003eNot applicable to quantitative monitoring hardware. However, if highly unexpected glucose results (e.g., repeatedly outside the standard 20–600 mg\/dL validation spectrum) appear on the screen, consult a doctor or contact SMS Pharmacy support immediately to eliminate systemic emergency risks.\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"16\"\u003eMissed Dose\u003c\/h2\u003e\n\u003cp data-path-to-node=\"17\"\u003ePerform your blood glucose check as soon as you remember. Ensure you coordinate your metabolic profiling times closely around primary target tracking windows (such as fasting or 2 hours post-meal) as outlined by your health specialist.\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"18\"\u003eHow To Use\u003c\/h2\u003e\n\u003cp data-path-to-node=\"19\"\u003eTo be used as per doctor's prescription and device guidelines. Always observe strict diagnostic hygiene:\u003c\/p\u003e\n\u003col start=\"1\" data-path-to-node=\"20\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"20,0,0\"\u003eWash hands thoroughly with warm, soapy water and dry them completely.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"20,1,0\"\u003eInsert a fresh, genuine Certeza GL-110 test strip into the meter strip slot. The device will turn on automatically.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"20,2,0\"\u003eClean the lancing site. Use the calibrated lancing device to yield a minuscule 0.6 µL drop of fresh capillary whole blood from the fingertip.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"20,3,0\"\u003eGently apply the sample drop to the target reaction tip of the test strip. The chamber will draw up the blood smoothly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"20,4,0\"\u003eThe countdown will begin, displaying highly accurate results on screen within 5 seconds. Press the strip ejector button to safely discard the single-use strip.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 data-path-to-node=\"21\"\u003eWhen Not to Use\u003c\/h2\u003e\n\u003cp data-path-to-node=\"22\"\u003eDo not use in case of:\u003c\/p\u003e\n\u003cul data-path-to-node=\"23\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"23,0,0\"\u003eIncompatibility with non-genuine diagnostic strips (the device works explicitly with Certeza GL-110 Test Strips)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"23,1,0\"\u003ePerforming systemic neonatal blood screening profiles, unless directed under a specialist physician's guidance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"23,2,0\"\u003eSevere diagnostic environments where the device hardware has been visibly fractured or exposed to extreme moisture entry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"24\"\u003eSide Effects\u003c\/h2\u003e\n\u003cp data-path-to-node=\"25\"\u003eSide effects are rare and limited completely to local lancing site interaction, including:\u003c\/p\u003e\n\u003cul data-path-to-node=\"26\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"26,0,0\"\u003eMinor localized tenderness or tissue soreness at the prick point\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"26,1,0\"\u003eMild temporary bruising or localized skin hardening from high-frequency testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"26,2,0\"\u003eMild surface irritation or localized redness\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"27\"\u003ePrecautions \u0026amp; Warnings\u003c\/h2\u003e\n\u003cp data-path-to-node=\"28\"\u003eFor diagnostic \u003ci data-path-to-node=\"28\" data-index-in-node=\"15\"\u003ein-vitro\u003c\/i\u003e tracking outside the body only. Keep the device dry and clean from biological fluids or grease residues. Never share your lancing device or lancets with others due to the immediate risk of cross-contamination and bloodborne pathogen transmission. Ensure the batteries are replaced promptly when the low-power indicator displays to preserve system processing stability.\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"29\"\u003eDrug Interactions\u003c\/h2\u003e\n\u003cp data-path-to-node=\"30\"\u003eDo not use if:\u003c\/p\u003e\n\u003cul data-path-to-node=\"31\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"31,0,0\"\u003eThe advanced GDH-FAD enzyme eliminates interference from non-glucose sugars like maltose or galactose. However, if undergoing systemic therapies with extraordinarily high concentrations of local reducing chemicals (such as toxic concentrations of Acetaminophen or Ascorbic Acid), check with your medical expert to monitor for minor electrochemical variations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"32\"\u003eFood Interactions\u003c\/h2\u003e\n\u003cp data-path-to-node=\"33\"\u003eThe food interactions that should be considered while using the Certeza GL-110 Meter are:\u003c\/p\u003e\n\u003cul data-path-to-node=\"34\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"34,0,0\"\u003eFood consumption does not affect the electronic mechanisms of the device. However, always ensure your puncture site is thoroughly cleansed of surface food stains, syrups, or fruit residues prior to testing, as external sugars will instantly trigger an artificially elevated blood glucose reading.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"35\"\u003eStorage\/Disposal\u003c\/h2\u003e\n\u003cp data-path-to-node=\"36\"\u003eStore the meter device inside its protective carrying case at a regulated temperature between 10°C and 40°C. Protect the internal microprocessor from high humidity, wet conditions, freezing points, or direct sunlight. Safely dispose of used lancets and contaminated strips inside dedicated biohazard sharps containers. Keep out of reach of children.\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"37\"\u003eControl Drug\u003c\/h2\u003e\n\u003cp data-path-to-node=\"38\"\u003eNo\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"39\"\u003eQuick Tips, if any\u003c\/h2\u003e\n\u003cul data-path-to-node=\"40\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"40,0,0\"\u003eUtilize the built-in test memory function to securely trace your previous glycemic trends over time, helping your doctor adjust your lifestyle or therapy plans.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"40,1,0\"\u003eChange your lancing site across different fingers for every test session to minimize the development of sensitive calluses or localized skin discomfort.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Certeza","offers":[{"title":"Default Title","offer_id":46691511795911,"sku":null,"price":2000.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0791\/0945\/6071\/files\/Gemini_Generated_Image_aleyh1aleyh1aley.webp?v=1782283638","url":"https:\/\/smspharmacy.pk\/products\/certeza-gl-110-blood-glucose-meter","provider":"SMS Pharmacy ","version":"1.0","type":"link"}