{"title":"Health Care Devices","description":"","products":[{"product_id":"oncall-plus-strip-50s-25-2","title":"Oncall Plus Strip 50's (25*2)","description":"\u003ch2 data-path-to-node=\"0\"\u003eDescription\u003c\/h2\u003e\n\u003cp data-path-to-node=\"1\"\u003eThe On Call Plus Blood Glucose Test Strips are premium, high-accuracy diagnostic tools engineered for precise quantitation of glucose levels in fresh capillary whole blood. Utilizing an advanced electrochemical \/ glucose oxidase biosensor method, these strips feature thin-film carbon electrodes paired with an auto-coding chip matrix to ensure supreme chemical calibration. Combined with fast-draw capillary technology, they rapidly pull the specimen into the reaction chamber, delivering laboratory-standard glycemic values from the comfort of home.\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"2\"\u003eIngredients\u003c\/h2\u003e\n\u003cp data-path-to-node=\"3\"\u003eEach test strip contains premium reactive chemicals:\u003c\/p\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003eGlucose Oxidase enzyme (Aspergillus niger)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003eElectron shuttle mediator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003eNon-reactive synthetic polymers and stabilization matrix\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"5\"\u003eDrug Class\u003c\/h2\u003e\n\u003cp data-path-to-node=\"6\"\u003eIn-Vitro Diagnostic Medical Device \/ Diabetes Management Supplies\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"7\"\u003eDosage Form\u003c\/h2\u003e\n\u003cp data-path-to-node=\"8\"\u003eTest Strips (Box of 50 pieces, packaged as 2 vials of 25 strips)\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"9\"\u003eUses\u003c\/h2\u003e\n\u003cp data-path-to-node=\"10\"\u003eIt is used to test and monitor metabolic health indices including:\u003c\/p\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003eDaily self-monitoring of blood glucose (SMBG) for Type 1 and Type 2 Diabetes mellitus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003eRoutine capillary blood sugar screening\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003eDetection of acute glycemic variations (Hyperglycemia and Hypoglycemia)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\"\u003eAlternate Site Testing (AST) protocols using the palm or forearm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,4,0\"\u003eClinical diagnostic tracking in home healthcare, nursing, and outpatient setups\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"12\"\u003eDosage\u003c\/h2\u003e\n\u003cp data-path-to-node=\"13\"\u003eTo be used as per doctor's prescription or tracking mandates (typically 1 to 4 times daily depending on your glycemic stability plan).\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"14\"\u003eIn case of Overdose\u003c\/h2\u003e\n\u003cp data-path-to-node=\"15\"\u003eNot applicable to topical or diagnostic components. However, if extreme blood glucose readings (below 20 mg\/dL or above 600 mg\/dL) are observed repeatedly, consult a doctor or contact SMS Pharmacy support immediately to rule out medical emergencies or system misuse.\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"16\"\u003eMissed Dose\u003c\/h2\u003e\n\u003cp data-path-to-node=\"17\"\u003ePerform your blood glucose tracking test as soon as you remember, especially if it relates to pre- or post-meal measurements. Do not use multiple strips simultaneously to correct a forgotten time slot.\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"18\"\u003eHow To Use\u003c\/h2\u003e\n\u003cp data-path-to-node=\"19\"\u003eTo be used as per doctor's prescription and device instructions. Always observe proper testing hygiene:\u003c\/p\u003e\n\u003col start=\"1\" data-path-to-node=\"20\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"20,0,0\"\u003eThoroughly wash your hands with warm water and soap, then dry completely.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"20,1,0\"\u003eInsert the specific code chip provided into your compatible On Call Plus\/EZ meter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"20,2,0\"\u003eRemove a single strip from the vial and immediately recap the vial tightly. Insert the strip into the meter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"20,3,0\"\u003eUse a sterile lancing device to acquire a tiny 0.5 µL drop of fresh whole blood from the fingertip or alternate site.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"20,4,0\"\u003eTouch the tip of the test strip to the blood drop until the reaction zone fills completely. Accurate results will display on-screen in 10 seconds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 data-path-to-node=\"21\"\u003eWhen Not to Use\u003c\/h2\u003e\n\u003cp data-path-to-node=\"22\"\u003eDo not use in case of:\u003c\/p\u003e\n\u003cul data-path-to-node=\"23\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"23,0,0\"\u003eIncompatibility with non-On Call systems (these strips work explicitly with On Call Plus and On Call EZ II glucometers)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"23,1,0\"\u003eSamples derived from neonatal blood testing, unless clinically calibrated by a physician\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"23,2,0\"\u003eStrips that have passed their explicit expiration date or have been exposed to open-air humidity for prolonged periods\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"24\"\u003eSide Effects\u003c\/h2\u003e\n\u003cp data-path-to-node=\"25\"\u003eSide effects are rare and limited entirely to local tissue puncturing, including:\u003c\/p\u003e\n\u003cul data-path-to-node=\"26\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"26,0,0\"\u003eMinor localized tenderness or pain at the puncture site\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"26,1,0\"\u003eTemporary bruising or skin calluses from frequent testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"26,2,0\"\u003eMild irritation or temporary redness\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"27\"\u003ePrecautions \u0026amp; Warnings\u003c\/h2\u003e\n\u003cp data-path-to-node=\"28\"\u003eFor diagnostic \u003ci data-path-to-node=\"28\" data-index-in-node=\"15\"\u003ein-vitro\u003c\/i\u003e testing outside the body only. Keep the internal desiccant cap sealed tight at all times; exposure to atmospheric ambient air will degrade the underlying glucose oxidase enzyme and trigger faulty lower readings. Ensure your hematocrit level stays within the validated 30-55% range for accurate data output. Do not reuse a strip once blood has interacted with the chemical window.\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"29\"\u003eDrug Interactions\u003c\/h2\u003e\n\u003cp data-path-to-node=\"30\"\u003eDo not use or consult your doctor if:\u003c\/p\u003e\n\u003cul data-path-to-node=\"31\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"31,0,0\"\u003eHigh concentrations of reducing substances such as Acetaminophen, Salicylates, Uric Acid, or Ascorbic Acid (Vitamin C) are present in the blood, as they can cause mild electrochemical interference and artificially shift reading results.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"32\"\u003eFood Interactions\u003c\/h2\u003e\n\u003cp data-path-to-node=\"33\"\u003eThe food interactions that should be considered while using On Call Plus Strips are:\u003c\/p\u003e\n\u003cul data-path-to-node=\"34\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"34,0,0\"\u003eFood choices do not affect the physical performance of the strips. However, ensure your fingertips are completely clean of food residues (like fruit sugar or juice film) before testing, as surface contaminants will artificially spike your blood sugar readouts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"35\"\u003eStorage\/Disposal\u003c\/h2\u003e\n\u003cp data-path-to-node=\"36\"\u003eStore the strips strictly within their original protective dual-vials between 15°C and 30°C. Protect from extreme heat, damp moisture, and direct sunlight. Do not freeze. Safely dispose of used lancets and test strips inside dedicated biohazard containers. Keep out of reach of children.\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"37\"\u003eControl Drug\u003c\/h2\u003e\n\u003cp data-path-to-node=\"38\"\u003eNo\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"39\"\u003eQuick Tips, if any\u003c\/h2\u003e\n\u003cul data-path-to-node=\"40\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"40,0,0\"\u003eNever transfer the test strips into a different or non-original container; the vial walls contain special moisture-absorbing agents that protect strip chemical longevity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"40,1,0\"\u003eRecord the exact opening date on the vial label; discard any remaining strips 3 months after opening the container to safeguard diagnostic accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Acon Usa","offers":[{"title":"Default Title","offer_id":46691387605191,"sku":null,"price":675.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0791\/0945\/6071\/files\/strip.webp?v=1782282416"},{"product_id":"free-style-strip-lite-100s","title":"Free Style Strip Lite 100'S","description":"\u003ch2 data-path-to-node=\"0\"\u003eDescription\u003c\/h2\u003e\n\u003cp data-path-to-node=\"1\"\u003eThe FreeStyle Lite Blood Glucose Test Strips are highly advanced, premium diagnostic tools engineered for the rapid quantitative measurement of glucose in fresh capillary whole blood. Utilizing an exclusive coulometry electrochemical measurement technique, these strips are completely unaffected by reaction rate variations. They feature innovative ZipWik tabs that instantly break the blood surface tension to wick up the specimen. Backed by No-Coding technology, they eliminate manual calibration errors, offering laboratory-standard accuracy to optimize daily diabetes management.\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"2\"\u003eIngredients\u003c\/h2\u003e\n\u003cp data-path-to-node=\"3\"\u003eEach test strip is treated with premium reactive chemistry:\u003c\/p\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003eFAD Glucose Dehydrogenase enzyme (Aspergillus oryzae): \u003cspan class=\"math-inline\" data-math=\"\\ge 1.0 \\text{ Unit}\" data-index-in-node=\"55\"\u003e$\\ge 1.0 \\text{ Unit}$\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003eOsmium-based mediator compound: \u003cspan class=\"math-inline\" data-math=\"\\ge 0.01 \\text{ mg}\" data-index-in-node=\"32\"\u003e$\\ge 0.01 \\text{ mg}$\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003eNon-reactive buffers, polymers, and stabilization agents\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"5\"\u003eDrug Class\u003c\/h2\u003e\n\u003cp data-path-to-node=\"6\"\u003eIn-Vitro Diagnostic Medical Device \/ Diabetes Management Supplies\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"7\"\u003eDosage Form\u003c\/h2\u003e\n\u003cp data-path-to-node=\"8\"\u003eTest Strips (Box of 100 pieces)\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"9\"\u003eUses\u003c\/h2\u003e\n\u003cp data-path-to-node=\"10\"\u003eIt is used to test, screen, and monitor metabolic glucose indices including:\u003c\/p\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003eDaily self-monitoring of blood glucose (SMBG) for Type 1 and Type 2 Diabetes mellitus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003eAlternate Site Testing (AST) protocols including the palm, forearm, upper arm, thigh, and calf\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003eImmediate quantitative assessment of glycemic extremes (Hyperglycemia and Hypoglycemia)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\"\u003eClinical tracking of insulin dose adjustments and dietary impact metrics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"12\"\u003eDosage\u003c\/h2\u003e\n\u003cp data-path-to-node=\"13\"\u003eTo be used as per doctor's prescription or individualized glycemic monitoring schedule.\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"14\"\u003eIn case of Overdose\u003c\/h2\u003e\n\u003cp data-path-to-node=\"15\"\u003eNot applicable to quantitative diagnostic equipment. However, if extreme glycemic readouts appear unexpectedly (e.g., repeatedly outside the standard 20–600 mg\/dL spectrum), consult a doctor or contact SMS Pharmacy support immediately to verify patient safety.\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"16\"\u003eMissed Dose\u003c\/h2\u003e\n\u003cp data-path-to-node=\"17\"\u003ePerform your blood sugar measurement as soon as you remember. Ensure you align tests closely with target testing windows (such as pre-meal or 2 hours post-meal) as outlined by your health specialist. Do not use multiple strips simultaneously.\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"18\"\u003eHow To Use\u003c\/h2\u003e\n\u003cp data-path-to-node=\"19\"\u003eTo be used as per doctor's prescription and compatible meter instructions. Always observe proper testing hygiene:\u003c\/p\u003e\n\u003col start=\"1\" data-path-to-node=\"20\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"20,0,0\"\u003eWash your hands thoroughly with warm, soapy water and dry them completely.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"20,1,0\"\u003eInsert a new FreeStyle Lite strip into a compatible meter (such as FreeStyle Lite or FreeStyle Freedom Lite). The meter will turn on automatically.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"20,2,0\"\u003eUse a sterile lancing device to extract a minuscule 0.3 µL drop of blood from the fingertip or an approved alternate site.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"20,3,0\"\u003eTouch the ZipWik tab on the side of the test strip to the blood drop. The strip will rapidly pull the specimen in.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"20,4,0\"\u003eIf the strip does not fill completely, you have up to 60 seconds to reapply more blood to the same area. A precise result will display on-screen within 5 seconds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 data-path-to-node=\"21\"\u003eWhen Not to Use\u003c\/h2\u003e\n\u003cp data-path-to-node=\"22\"\u003eDo not use in case of:\u003c\/p\u003e\n\u003cul data-path-to-node=\"23\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"23,0,0\"\u003eIncompatibility with non-approved monitoring systems (explicitly designed for FreeStyle Lite, FreeStyle Freedom Lite, and FreeStyle InsuLinx systems only)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"23,1,0\"\u003eTesting utilizing samples from neonatal blood screening, unless calibrated explicitly under specialist orders\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"23,2,0\"\u003eStrips where the package seal is broken or the expiration date printed on the vial has passed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"24\"\u003eSide Effects\u003c\/h2\u003e\n\u003cp data-path-to-node=\"25\"\u003eSide effects are rare and confined entirely to the localized puncture site, including:\u003c\/p\u003e\n\u003cul data-path-to-node=\"26\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"26,0,0\"\u003eMinor localized tenderness or structural skin soreness at the puncture zone\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"26,1,0\"\u003eTemporary bruising or minor skin calluses from frequent lancing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"26,2,0\"\u003eMild surface irritation or temporary redness\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"27\"\u003ePrecautions \u0026amp; Warnings\u003c\/h2\u003e\n\u003cp data-path-to-node=\"28\"\u003eFor diagnostic \u003ci data-path-to-node=\"28\" data-index-in-node=\"15\"\u003ein-vitro\u003c\/i\u003e testing outside the body only. Do not reuse test strips; they are strictly designed for single-use application. To protect the integrity of the active FAD-GDH enzymes, keep the vial cap tightly closed immediately after extracting a strip. Ensure your hematocrit levels are within the validated 15% to 65% operational spectrum to safeguard data accuracy.\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"29\"\u003eDrug Interactions\u003c\/h2\u003e\n\u003cp data-path-to-node=\"30\"\u003eDo not use or consult your doctor if:\u003c\/p\u003e\n\u003cul data-path-to-node=\"31\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"31,0,0\"\u003eThe system utilizes a low potential for mediator oxidation to minimize interference. However, exceptionally high systemic levels of electrochemically active reducing substances (such as toxic concentrations of Acetaminophen, Ascorbic acid, or Uric acid) should be monitored, as they may slightly skew data output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"32\"\u003eFood Interactions\u003c\/h2\u003e\n\u003cp data-path-to-node=\"33\"\u003eThe food interactions that should be considered while using FreeStyle Lite Strips are:\u003c\/p\u003e\n\u003cul data-path-to-node=\"34\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"34,0,0\"\u003eFood intake does not interfere with the biochemical mechanisms of the strip. However, ensure testing fingers are completely free from food oils or fruit sugars prior to lancing, as surface contaminants will falsely elevate glucose readouts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"35\"\u003eStorage\/Disposal\u003c\/h2\u003e\n\u003cp data-path-to-node=\"36\"\u003eStore exclusively within the original protective desiccant vial at a regulated room temperature between 4°C and 30°C. Protect from high humidity, freezing conditions, and direct sunlight. Safely discard used lancets and bio-interactive test strips inside dedicated sharps bins. Keep out of reach of children.\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"37\"\u003eControl Drug\u003c\/h2\u003e\n\u003cp data-path-to-node=\"38\"\u003eNo\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"39\"\u003eQuick Tips, if any\u003c\/h2\u003e\n\u003cul data-path-to-node=\"40\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"40,0,0\"\u003eNever transfer strips to a generic container; the original vial walls contain specialized drying agents essential for chemical shelf-life.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"40,1,0\"\u003eTake advantage of the ultra-small 0.3 µL sample demand—the world's smallest volume requirement—allowing you to use shallower lancing depths for a completely pain-free testing routine.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Abbot Laboratories (Pak) Ltd","offers":[{"title":"Default Title","offer_id":46691463758023,"sku":null,"price":8000.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0791\/0945\/6071\/files\/Gemini_Generated_Image_hzwagahzwagahzwa.webp?v=1782283081"},{"product_id":"certeza-gl-110-blood-glucose-meter","title":"Certeza (Gl 110) Blood Glucose Meter","description":"\u003ch2 data-path-to-node=\"0\"\u003eDescription\u003c\/h2\u003e\n\u003cp data-path-to-node=\"1\"\u003eThe Certeza GL-110 Blood Glucose Monitor is a highly precise, user-friendly diagnostic medical instrument designed for regular monitoring of capillary blood glucose levels. Engineered with an advanced dynamic enzyme system featuring Glucose Dehydrogenase (GDH-FAD) chemistry, it offers extensive reaction stability unaffected by variations in blood oxygen levels. The system features a large, easy-to-read LCD screen, auto-coding mechanisms to eliminate manual calibration errors, and automatic strip ejection functionality, providing laboratory-grade diagnostic clarity for optimal daily diabetes care.\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"2\"\u003eIngredients\u003c\/h2\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe diagnostic device includes integrated electronic hardware. The dedicated system consumables feature:\u003c\/p\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003eGlucose Dehydrogenase enzyme matrix (GDH-FAD)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003eElectrochemical carbon-based electrodes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"5\"\u003eDrug Class\u003c\/h2\u003e\n\u003cp data-path-to-node=\"6\"\u003eIn-Vitro Diagnostic Medical Device \/ Glucose Monitoring System\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"7\"\u003eDosage Form\u003c\/h2\u003e\n\u003cp data-path-to-node=\"8\"\u003eBlood Glucose Meter (1 Kit including Glucometer, Lancing Device, Lancets, and Carrying Case)\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"9\"\u003eUses\u003c\/h2\u003e\n\u003cp data-path-to-node=\"10\"\u003eIt is used to test, screen, and log metabolic glucose indexes including:\u003c\/p\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003eDaily self-monitoring of blood glucose (SMBG) for Type 1 and Type 2 Diabetes mellitus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003eRapid quantitative measurement of extreme glycemic variances (Hyperglycemia and Hypoglycemia)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003eRoutine diagnostic tracing of capillary glucose variations in home-care and clinical health environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"12\"\u003eDosage\u003c\/h2\u003e\n\u003cp data-path-to-node=\"13\"\u003eTo be used as per doctor's prescription or tracking mandates (ranging from 1 to 4 times daily depending on individual health profiles).\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"14\"\u003eIn case of Overdose\u003c\/h2\u003e\n\u003cp data-path-to-node=\"15\"\u003eNot applicable to quantitative monitoring hardware. However, if highly unexpected glucose results (e.g., repeatedly outside the standard 20–600 mg\/dL validation spectrum) appear on the screen, consult a doctor or contact SMS Pharmacy support immediately to eliminate systemic emergency risks.\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"16\"\u003eMissed Dose\u003c\/h2\u003e\n\u003cp data-path-to-node=\"17\"\u003ePerform your blood glucose check as soon as you remember. Ensure you coordinate your metabolic profiling times closely around primary target tracking windows (such as fasting or 2 hours post-meal) as outlined by your health specialist.\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"18\"\u003eHow To Use\u003c\/h2\u003e\n\u003cp data-path-to-node=\"19\"\u003eTo be used as per doctor's prescription and device guidelines. Always observe strict diagnostic hygiene:\u003c\/p\u003e\n\u003col start=\"1\" data-path-to-node=\"20\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"20,0,0\"\u003eWash hands thoroughly with warm, soapy water and dry them completely.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"20,1,0\"\u003eInsert a fresh, genuine Certeza GL-110 test strip into the meter strip slot. The device will turn on automatically.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"20,2,0\"\u003eClean the lancing site. Use the calibrated lancing device to yield a minuscule 0.6 µL drop of fresh capillary whole blood from the fingertip.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"20,3,0\"\u003eGently apply the sample drop to the target reaction tip of the test strip. The chamber will draw up the blood smoothly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"20,4,0\"\u003eThe countdown will begin, displaying highly accurate results on screen within 5 seconds. Press the strip ejector button to safely discard the single-use strip.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 data-path-to-node=\"21\"\u003eWhen Not to Use\u003c\/h2\u003e\n\u003cp data-path-to-node=\"22\"\u003eDo not use in case of:\u003c\/p\u003e\n\u003cul data-path-to-node=\"23\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"23,0,0\"\u003eIncompatibility with non-genuine diagnostic strips (the device works explicitly with Certeza GL-110 Test Strips)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"23,1,0\"\u003ePerforming systemic neonatal blood screening profiles, unless directed under a specialist physician's guidance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"23,2,0\"\u003eSevere diagnostic environments where the device hardware has been visibly fractured or exposed to extreme moisture entry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"24\"\u003eSide Effects\u003c\/h2\u003e\n\u003cp data-path-to-node=\"25\"\u003eSide effects are rare and limited completely to local lancing site interaction, including:\u003c\/p\u003e\n\u003cul data-path-to-node=\"26\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"26,0,0\"\u003eMinor localized tenderness or tissue soreness at the prick point\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"26,1,0\"\u003eMild temporary bruising or localized skin hardening from high-frequency testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"26,2,0\"\u003eMild surface irritation or localized redness\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"27\"\u003ePrecautions \u0026amp; Warnings\u003c\/h2\u003e\n\u003cp data-path-to-node=\"28\"\u003eFor diagnostic \u003ci data-path-to-node=\"28\" data-index-in-node=\"15\"\u003ein-vitro\u003c\/i\u003e tracking outside the body only. Keep the device dry and clean from biological fluids or grease residues. Never share your lancing device or lancets with others due to the immediate risk of cross-contamination and bloodborne pathogen transmission. Ensure the batteries are replaced promptly when the low-power indicator displays to preserve system processing stability.\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"29\"\u003eDrug Interactions\u003c\/h2\u003e\n\u003cp data-path-to-node=\"30\"\u003eDo not use if:\u003c\/p\u003e\n\u003cul data-path-to-node=\"31\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"31,0,0\"\u003eThe advanced GDH-FAD enzyme eliminates interference from non-glucose sugars like maltose or galactose. However, if undergoing systemic therapies with extraordinarily high concentrations of local reducing chemicals (such as toxic concentrations of Acetaminophen or Ascorbic Acid), check with your medical expert to monitor for minor electrochemical variations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"32\"\u003eFood Interactions\u003c\/h2\u003e\n\u003cp data-path-to-node=\"33\"\u003eThe food interactions that should be considered while using the Certeza GL-110 Meter are:\u003c\/p\u003e\n\u003cul data-path-to-node=\"34\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"34,0,0\"\u003eFood consumption does not affect the electronic mechanisms of the device. However, always ensure your puncture site is thoroughly cleansed of surface food stains, syrups, or fruit residues prior to testing, as external sugars will instantly trigger an artificially elevated blood glucose reading.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"35\"\u003eStorage\/Disposal\u003c\/h2\u003e\n\u003cp data-path-to-node=\"36\"\u003eStore the meter device inside its protective carrying case at a regulated temperature between 10°C and 40°C. Protect the internal microprocessor from high humidity, wet conditions, freezing points, or direct sunlight. Safely dispose of used lancets and contaminated strips inside dedicated biohazard sharps containers. Keep out of reach of children.\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"37\"\u003eControl Drug\u003c\/h2\u003e\n\u003cp data-path-to-node=\"38\"\u003eNo\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"39\"\u003eQuick Tips, if any\u003c\/h2\u003e\n\u003cul data-path-to-node=\"40\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"40,0,0\"\u003eUtilize the built-in test memory function to securely trace your previous glycemic trends over time, helping your doctor adjust your lifestyle or therapy plans.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"40,1,0\"\u003eChange your lancing site across different fingers for every test session to minimize the development of sensitive calluses or localized skin discomfort.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Certeza","offers":[{"title":"Default Title","offer_id":46691511795911,"sku":null,"price":2000.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0791\/0945\/6071\/files\/Gemini_Generated_Image_aleyh1aleyh1aley.webp?v=1782283638"},{"product_id":"certeza-gs-807-digital-glass-scale","title":"Certeza Gs-807 Digital Glass Scale","description":"\u003ch2 data-path-to-node=\"0\" class=\"\"\u003eDescription\u003c\/h2\u003e\n\u003cp data-path-to-node=\"1\"\u003e\u003cspan class=\"\"\u003eThe Certeza GS-807 Digital Glass Scale is a premium,\u003c\/span\u003e\u003cspan class=\"\"\u003e high-precision electronic weight monitoring instrument designed for accurate body weight management.\u003c\/span\u003e\u003cspan class=\"\"\u003e Engineered with an advanced 4-sensor strain gauge technology,\u003c\/span\u003e\u003cspan class=\"\"\u003e it ensures reliable weight distribution analysis and repeatable measurement precision.\u003c\/span\u003e\u003cspan class=\"\"\u003e Featuring a sleek,\u003c\/span\u003e\u003cspan class=\"\"\u003e heavy-duty tempered safety glass platform,\u003c\/span\u003e\u003cspan class=\"\"\u003e an easy-to-read widescreen LCD display,\u003c\/span\u003e\u003cspan class=\"\"\u003e and energy-efficient auto-on\/off functionality,\u003c\/span\u003e\u003cspan class=\"\"\u003e this scale offers medical-standard tracking clarity to support your fitness and health goals.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"2\" class=\"\"\u003eIngredients\u003c\/h2\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe health monitoring device includes integrated electronic hardware.\u003c\/span\u003e\u003cspan class=\"\"\u003e The structural components feature:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003e\u003cspan class=\"\"\u003ePremium tempered safety glass platform\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003e\u003cspan class=\"\"\u003eHigh-precision strain gauge sensors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003e\u003cspan class=\"\"\u003eIntegrated digital microprocessor and LCD display screen\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"5\" class=\"\"\u003eDrug Class\u003c\/h2\u003e\n\u003cp data-path-to-node=\"6\"\u003e\u003cspan class=\"\"\u003eDiagnostic Medical Equipment \/ Personal Health Monitoring Device\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"7\" class=\"\"\u003eDosage Form\u003c\/h2\u003e\n\u003cp data-path-to-node=\"8\"\u003e\u003cspan class=\"\"\u003eDigital Weighing Scale (1 Kit containing 1 Electronic Scale,\u003c\/span\u003e\u003cspan class=\"\"\u003e User Manual,\u003c\/span\u003e\u003cspan class=\"\"\u003e and Batteries)\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"9\" class=\"\"\u003eUses\u003c\/h2\u003e\n\u003cp data-path-to-node=\"10\"\u003e\u003cspan class=\"\"\u003eIt is used to test,\u003c\/span\u003e\u003cspan class=\"\"\u003e screen,\u003c\/span\u003e\u003cspan class=\"\"\u003e and log physical health parameters including:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"11\" class=\"animating\"\u003e\n\u003cli class=\"animating\"\u003e\n\u003cp data-path-to-node=\"11,0,0\" class=\"animating\"\u003e\u003cspan class=\"\"\u003eRegular tracking and monitoring of total body weight\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"animating\"\u003e\n\u003cp data-path-to-node=\"11,1,0\" class=\"animating\"\u003e\u003cspan class=\"\"\u003eManagement and evaluation of dietary regimens,\u003c\/span\u003e\u003cspan class=\"\"\u003e fitness programs,\u003c\/span\u003e\u003cspan class=\"\"\u003e and obesity treatments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"animating\"\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cspan class=\"\"\u003eRoutine weight monitoring for metabolic,\u003c\/span\u003e\u003cspan class=\"\"\u003e cardiovascular,\u003c\/span\u003e\u003cspan class=\"\"\u003e or physical therapy tracking in home-care environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"12\" class=\"\"\u003eDosage\u003c\/h2\u003e\n\u003cp data-path-to-node=\"13\"\u003e\u003cspan class=\"\"\u003eTo be used as per doctor's prescription or personal tracking mandates (typically measured once daily or weekly under consistent conditions).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"14\" class=\"\"\u003eIn case of Overdose\u003c\/h2\u003e\n\u003cp data-path-to-node=\"15\"\u003e\u003cspan class=\"\"\u003eNot applicable to non-consumable monitoring hardware.\u003c\/span\u003e\u003cspan class=\"\"\u003e However,\u003c\/span\u003e\u003cspan class=\"\"\u003e if the scale is subjected to loads exceeding its maximum capacity specification (up to 180 kg \/ 396 lbs),\u003c\/span\u003e\u003cspan class=\"\"\u003e structural strain or sensor errors may occur.\u003c\/span\u003e\u003cspan class=\"\"\u003e Contact SMS Pharmacy support if you suspect calibration errors.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"16\" class=\"\"\u003eMissed Dose\u003c\/h2\u003e\n\u003cp data-path-to-node=\"17\"\u003e\u003cspan class=\"\"\u003ePerform your weight tracking measurement as soon as you remember.\u003c\/span\u003e\u003cspan class=\"\"\u003e For the highest diagnostic consistency,\u003c\/span\u003e\u003cspan class=\"\"\u003e ensure you coordinate your weight logging at the same time of day (preferably in the morning,\u003c\/span\u003e\u003cspan class=\"\"\u003e fasting,\u003c\/span\u003e\u003cspan class=\"\"\u003e and before dressing),\u003c\/span\u003e\u003cspan class=\"\"\u003e as outlined by your health specialist.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"18\" class=\"\"\u003eHow To Use\u003c\/h2\u003e\n\u003cp data-path-to-node=\"19\"\u003e\u003cspan class=\"\"\u003eTo be used as per doctor's prescription or personal monitoring guidelines.\u003c\/span\u003e\u003cspan class=\"\"\u003e Always observe stable testing conditions:\u003c\/span\u003e\u003c\/p\u003e\n\u003col start=\"1\" data-path-to-node=\"20\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"20,0,0\"\u003e\u003cspan class=\"\"\u003ePlace the Certeza GS-807 scale on a completely flat,\u003c\/span\u003e\u003cspan class=\"\"\u003e hard,\u003c\/span\u003e\u003cspan class=\"\"\u003e and solid floor surface.\u003c\/span\u003e\u003cspan class=\"\"\u003e Avoid placing it on carpets or soft rugs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"20,1,0\"\u003e\u003cspan class=\"\"\u003eStep directly onto the center of the tempered glass platform without shaking or moving your body.\u003c\/span\u003e\u003cspan class=\"\"\u003e The auto-on technology will instantly activate the digital sensors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"20,2,0\"\u003e\u003cspan class=\"\"\u003eStand completely still while the scale analyzes your weight distribution.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"20,3,0\"\u003e\u003cspan class=\"\"\u003eWithin a few seconds,\u003c\/span\u003e\u003cspan class=\"\"\u003e the weight reading will flash and lock on the widescreen LCD display.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"20,4,0\"\u003e\u003cspan class=\"\"\u003eStep off the scale.\u003c\/span\u003e\u003cspan class=\"\"\u003e The energy-saving auto-off mechanism will automatically shut down the screen after a brief period of inactivity.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 data-path-to-node=\"21\" class=\"\"\u003eWhen Not to Use\u003c\/h2\u003e\n\u003cp data-path-to-node=\"22\"\u003e\u003cspan class=\"\"\u003eDo not use in case of:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"23\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"23,0,0\"\u003e\u003cspan class=\"\"\u003eUnstable or uneven floor surfaces that compromise sensor leveling and user balance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"23,1,0\"\u003e\u003cspan class=\"\"\u003eSevere structural environments where the tempered glass platform has been visibly cracked,\u003c\/span\u003e\u003cspan class=\"\"\u003e fractured,\u003c\/span\u003e\u003cspan class=\"\"\u003e or deeply scratched\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"23,2,0\"\u003e\u003cspan class=\"\"\u003eExceeding the maximum structural weight capacity limit of 180 kg (396 lbs)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"24\" class=\"\"\u003eSide Effects\u003c\/h2\u003e\n\u003cp data-path-to-node=\"25\"\u003e\u003cspan class=\"\"\u003eSide effects are rare and limited completely to accidental physical slips,\u003c\/span\u003e\u003cspan class=\"\"\u003e including:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"26\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"26,0,0\"\u003e\u003cspan class=\"\"\u003eLoss of footing or slipping if stepping onto the glass platform with wet feet or a damp surface\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"26,1,0\"\u003e\u003cspan class=\"\"\u003eTemporary footprint marks on skin from cold glass contact\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"27\" class=\"\"\u003ePrecautions \u0026amp; Warnings\u003c\/h2\u003e\n\u003cp data-path-to-node=\"28\"\u003e\u003cspan class=\"\"\u003eFor diagnostic \u003c\/span\u003e\u003ci data-path-to-node=\"28\" data-index-in-node=\"15\" class=\"\"\u003ein-vitro\u003c\/i\u003e\u003cspan class=\"\"\u003e tracking and external body weight evaluation only.\u003c\/span\u003e\u003cspan class=\"\"\u003e Keep the scale surface dry; never step onto the platform with wet feet or when the glass surface is damp,\u003c\/span\u003e\u003cspan class=\"\"\u003e as it creates an immediate slip hazard.\u003c\/span\u003e\u003cspan class=\"\"\u003e Avoid dropping heavy objects onto the platform or subjecting the corners to sharp impacts,\u003c\/span\u003e\u003cspan class=\"\"\u003e as this can shatter the safety glass.\u003c\/span\u003e\u003cspan class=\"\"\u003e Ensure the batteries are replaced promptly when the low-power indicator displays to preserve system processing and calibration stability.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"29\" class=\"\"\u003eDrug Interactions\u003c\/h2\u003e\n\u003cp data-path-to-node=\"30\"\u003e\u003cspan class=\"\"\u003eDo not use if:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"31\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"31,0,0\"\u003e\u003cspan class=\"\"\u003ePhysical weight tracking does not interact with medicinal therapies.\u003c\/span\u003e\u003cspan class=\"\"\u003e However,\u003c\/span\u003e\u003cspan class=\"\"\u003e if using the scale to track fluid retention changes during systemic diuretic therapies (e.\u003c\/span\u003e\u003cspan class=\"\"\u003eg.,\u003c\/span\u003e\u003cspan class=\"\"\u003e for heart failure or kidney disease),\u003c\/span\u003e\u003cspan class=\"\"\u003e check with your medical expert to align weight-tracking guidelines with your prescription.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"32\" class=\"\"\u003eFood Interactions\u003c\/h2\u003e\n\u003cp data-path-to-node=\"33\"\u003e\u003cspan class=\"\"\u003eThe food interactions that should be considered while using the Certeza GS-807 Scale are:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"34\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"34,0,0\"\u003e\u003cspan class=\"\"\u003eFood consumption does not affect the electronic mechanisms of the device.\u003c\/span\u003e\u003cspan class=\"\"\u003e However,\u003c\/span\u003e\u003cspan class=\"\"\u003e remember that eating heavy meals or drinking large volumes of fluid right before stepping on the scale will temporarily alter your body mass reading.\u003c\/span\u003e\u003cspan class=\"\"\u003e For accurate long-term trends,\u003c\/span\u003e\u003cspan class=\"\"\u003e always weigh yourself under identical fasting or post-meal conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-path-to-node=\"35\" class=\"\"\u003eStorage\/Disposal\u003c\/h2\u003e\n\u003cp data-path-to-node=\"36\"\u003e\u003cspan class=\"\"\u003eStore the scale in a cool,\u003c\/span\u003e\u003cspan class=\"\"\u003e dry room at a regulated temperature.\u003c\/span\u003e\u003cspan class=\"\"\u003e Keep the glass platform clean from household grease,\u003c\/span\u003e\u003cspan class=\"\"\u003e dust,\u003c\/span\u003e\u003cspan class=\"\"\u003e or moisture entry.\u003c\/span\u003e\u003cspan class=\"\"\u003e Store the scale horizontally; do not store it standing vertically against a wall as this can permanently unbalance the internal sensors over time.\u003c\/span\u003e\u003cspan class=\"\"\u003e Safely dispose of old batteries according to local electronic waste guidelines.\u003c\/span\u003e\u003cspan class=\"\"\u003e Keep out of reach of infants.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"37\" class=\"\"\u003eControl Drug\u003c\/h2\u003e\n\u003cp data-path-to-node=\"38\"\u003e\u003cspan class=\"\"\u003eNo\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-path-to-node=\"39\" class=\"\"\u003eQuick Tips, if any\u003c\/h2\u003e\n\u003cul data-path-to-node=\"40\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"40,0,0\"\u003e\u003cspan class=\"\"\u003eUtilize the integrated unit conversion button (typically located on the underside of the scale) to seamlessly switch your display data between kilograms (kg),\u003c\/span\u003e\u003cspan class=\"\"\u003e pounds (lb),\u003c\/span\u003e\u003cspan class=\"\"\u003e or stones (st) according to your tracking preference.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"40,1,0\"\u003e\u003cspan\u003eNever use abrasive chemical sprays or harsh detergents to clean the glass platform; a light wipe with a damp,\u003c\/span\u003e\u003cspan\u003e lint-free cloth is all that is required to preserve the surface finish.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Certeza","offers":[{"title":"Default Title","offer_id":46691550691527,"sku":null,"price":3000.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0791\/0945\/6071\/files\/Gemini_Generated_Image_k5aot9k5aot9k5ao.webp?v=1782284456"}],"url":"https:\/\/smspharmacy.pk\/collections\/health-care-devices.oembed","provider":"SMS Pharmacy ","version":"1.0","type":"link"}